Interactive marketing demo running on Vercel with mock data. Click any feature to explore — no account needed.
Production stack for AssayCore Tracker
Core: PostgreSQL 16 + Redis 7 + Kafka 3.7 + MinIO + Keycloak 24 + Spring Boot 3.3 (Kotlin) + React 18/MUI + FastAPI ML (Python 3.11) + Nginx + Docker
Module-specific: Code 128 / DataMatrix / QR with check-digit · IoT temperature loggers (BLE + LoRaWAN ingest) · IATA DGR shipment builder · Zebra ZPL / Brady / DYMO label printer drivers · Free-migration ETL toolkit (LabWare LIMS Basic / SampleManager VGL / STARLIMS source recipes)
Deployable on your infrastructure or our managed Hetzner. Self-hosted source-license available.
Temperature Excursions
Alarm → Acknowledge → CAPA → Root cause · 21 CFR Part 11 e-sign · GxP audit trail
1 active excursion - immediate action required
GDP SOP-TMP-004: Acknowledge within 30 minutes. Initiate sample integrity assessment. Open CAPA record.
Active alarms
1
Critical events
1
CAPA open
2
Samples affected
240
Closed
5
| Excursion ID | Site / Unit | Peak °C | Severity | Samples | Impact | Status |
|---|---|---|---|---|---|---|
EXC-2026-0417-001 2026-04-17 03:14:00 | Westside Clinic Freezer Rack C-4 | 12.4 °C range 2–8 | major | 22 affected | Under integrity review | CAPA Open |
EXC-2026-0417-002 2026-04-17 06:02:00 | Metro Biobank ULT Freezer B-02 (−80°C) | -62.1 °C range -90–-70 | critical | 118 affected | Quarantined | Acknowledged |
EXC-2026-0416-003 2026-04-16 14:30:00 | Research Lab Beta Refrigerator R-01 (2–8°C) | 10.8 °C range 2–8 | minor | 8 affected | Cleared - integrity OK | CAPA Closed |
EXC-2026-0416-004 2026-04-16 22:10:00 | City General Hospital Blood Bank Fridge BB-01 | 9.2 °C range 2–8 | minor | 14 affected | Cleared - integrity OK | Closed |
EXC-2026-0415-005 2026-04-15 11:40:00 | Northern Field Station In-transit Reefer Box TRK-014 | 14.7 °C range 2–8 | major | 36 affected | Under integrity review | CAPA Open |
EXC-2026-0414-006 2026-04-14 09:05:00 | Research Lab Gamma Incubator INC-02 (37°C) | 41.3 °C range 35–39 | major | 6 affected | Confirmed compromised | Closed |
EXC-2026-0413-007 2026-04-13 04:50:00 | Metro Biobank ULT Freezer A-01 (−80°C) | -67.8 °C range -90–-70 | minor | 0 affected | No samples affected | Closed |
EXC-2026-0412-008 2026-04-12 13:00:00 | Eastside Clinic Ambient Room AMBT-01 | 28.4 °C range 15–25 | minor | 5 affected | Cleared - integrity OK | Closed |
EXC-2026-0410-009 2026-04-10 07:20:00 | Research Lab Alpha ULT Freezer F-01 (−80°C) | -69.1 °C range -90–-70 | minor | 0 affected | No samples affected | Closed |
EXC-2026-0408-010 2026-04-08 18:40:00 | City General Hospital Serology Fridge SER-03 (2–8°C) | 11.6 °C range 2–8 | major | 31 affected | Cleared - integrity OK | CAPA Closed |